MINIATURE TENSION LOAD CELLS
SUMM, SUMMA

Á¦Ç° »ç¾ç īŸ·Î±× pdf ÆÄÀÏ  
catalog 

 FEATURE

 ÃʼÒÇüÀ¸·Î ½ºÅÙ·¹½º ½ºÆ¿ ÀçÁúÀ» »ç¿ëÇÏ¿© ³»½Ä¼ºÀÌ ¿ì¼öÇϸç ÀÎÀå, ¾ÐÃàÀÌ °¡´ÉÇÑ ¸ðµ¨ÀÔ´Ï´Ù.
 ÀüÀÚÁ¦Ç°ÀÇ ¾ÐÀÔ·Â °ü¸®¿ëÀ̳ª Àú¿ë·®ÀÇ ÀÎÀå ¾ÐÃà ÃøÁ¤¿¡ »ç¿ëµÇ´Â °ÍÀ¸·Î ºñ±³Àû Á¤¹Ðµµ°¡ ³ôÀ¸¸ç °íÁ¤ ³ª»çºÎ¸¦ °¡Áø °ÍÀÌ Æ¯Â¡ÀÔ´Ï´Ù.

SUMM (Unit : mm) SUMMA (Unit : mm)

 

DIMENSION TABLE (unit : mm)

Capacity SUMM SUMMA
A B C D E F A B C D E F
1 ~ 5kgf 23 34 20 M3×0.5 14 - 23 20 10 M3×0.5 18 M3DP8
10 ~ 200kgf 27 37 30 M6×1 17 - 27 21 11 M6×1 22 M3DP8

  SPECIFICATION

  SUMM SUMMA
Rated capacity (R.C) 1,2,5,10,20,50,100,200kgf 1,2,5,10,20,50,100,200kgf
Rated output (R.O) 0.7mV/V ~ 1.2mV/V 0.7mV/V ~ 1.2mV/V
Nonlinearity 0.1% R.O. 0.1% R.O.
Hysteresis 0.1% R.O. 0.1% R.O.
Repeatability 0.1% R.O. 0.1% R.O.
Zero balance ±2% R.O ±2% R.O
Temperature effect, on rated output 0.1% LOAD/10¡É 0.1% LOAD/10¡É
Temperature effect, on zero balance 0.05% R.O./10¡É 0.05% R.O./10¡É
Temperature range, compensated -10 ~ 70¡É -10 ~ 70¡É
Temperature range, safe -10 ~ 80¡É -10 ~ 80¡É
Terminal resistance input 350 ±30¥Ø 350 ±30¥Ø
Terminal resistance output 350 ±2¥Ø 350 ±2¥Ø
Insulation resistance bridge/case 2000M¥Ø 2000M¥Ø
Excitation recommended 5V 5V
Safe overload 120% R.C 120% R.C
Cable length ø3.4core shield cable, 2m ø3.4core shield cable, 2m

 

 

 